Anti-doping lab validates blood tests detecting semaglutide, tirzepatide
Mass spectrometry methods reached detection limits of 0.48 ng/mL for tirzepatide in serum, with dried blood spots also workable for the lipidated peptides.
PR
By Priya Raman · Science Reporter
The wire
- 01Researchers validated LC-HRMS/MS methods for five GLP-1 receptor agonists and the metabolite GLP-1(9-36)-NH2, using antibody magnetic-bead purification for exenatide, lixisenatide and the metabolite, with detection limits from 9.4 to 48 pg/mL in 100 microlitres of serum.
- 02Semaglutide and tirzepatide are not prohibited but sit on the World Anti-Doping Agency Monitoring Program, so validated assays allow surveillance of use among athletes.
- 03Methods were confirmed with post-administration human samples for semaglutide and tirzepatide and murine samples for the others; these are qualitative detection methods, not quantitative or prevalence data.
From the source
Read at pubmed.ncbi.nlm.nih.govDevelopment and validation of qualitative methods for the detection of GLP-1 receptor agonists in serum and dried blood spots by LC-HRMS/MS for doping control purposes
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026 Oct 8 · Borschel L, Thomas A, Studer D et al.
Source URL https://pubmed.ncbi.nlm.nih.gov/42874322/